Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model: SPST300VAC15000W-4-17
merk: APM
Plaats Van Herkomst: China
Input Frequency: 47~63hz
Input Voltage: 190~265v
Power Factor: ≥0.99
Max.Current: 90a
Height: 17u
Warranty: 2 Years
Interface: Rs232/Rs485/Usb(Standard)
AC Power(Total): 15000va
AC Power(Per Phase): 5000va
verpakkingen: driefasige ac-stroomlijnen
produktiviteit: OTHER
vervoer: Air
Plaats van herkomst: CHINA
Ondersteuning over: OTHER
Certificaat: ISO9001
GS-code: 8504401500
Haven: DHL
betaling Type: T/T
Incoterm: EXW
APM focus op AC-voedingontwerp, dat zich inhoudt om een hoogwaardige 3-fase programmeerbare AC-bron met hoge betrouwbaarheid te bieden. Dit model omvat het vermogensbereik tot 15 kVA, waardoor pure 3-fase AC-kracht en DC-vermogen wordt geleverd. Gebruikers kunnen frequentie en spanning programmeren, de belangrijke kenmerken van de output op het grote scherm meten. De 3 -fase voeding is ook geschikt voor commerciële toepassingen, van laboratoriumtests tot massaproducties .
Er zijn meer modellen, 1800W 3 fase AC -bron en 3000W 3 fase AC -bron, 4500W 3 fase AC -bron, 6000W driefasige AC -bronsysteem, 9000W driefasige AC -bronsysteem voor uw referentie.
Applicatiegebied :
Deze serie is van toepassing op meerdere sectoren zoals elektrische, verlichting- en luchtvaartsectoren en kan ook worden toegepast op de productietest van Enterprise.
Producteigenschappen:
● 5.6`` Grote aanraakkleurscherm, bezit volledige functies en gemakkelijk te bedienen.
● Ondersteuning voor USB -gegevens Import/exporteren en screenknap vanuit het voorpaneel.
● AC+DC gemengde of onafhankelijke uitgangsmodus voor spannings DC Offset -simulatie.
● Ondersteuning voor het instellen van spanning en stroomuitgangsbeperking voor de uitgangsmodus van de constante stroom.
● In staat om de uitgangshelling van spanning en frequentie in te stellen.
● In staat om fase -hoek in te stellen.
● Met omgekeerde stroombeveiliging om te voorkomen dat de stroom naar achteren stroomt.
● Ingebouwde vermogensmeter, die in staat is om 5 elektrische parameters per fase te meten, inclusief spanning, stroom, vermogen, enz.
● Ondersteuning van MA -huidige meetfunctie.
Basisfuncties:
1. Verstelbare fasehoek/helling
Instelbare fasehoek/helling is van toepassing op verificatietest van aan/uit -inrushstroomtests. Deze functie is van toepassing om inductieve of capacitieve belasting te starten met grote capaciteit om hoge stroom te voorkomen wanneer het apparaat onmiddellijk start.
2. Hoge uitgangsstroom Crest -factor
De overspanningsstroom kan 5-6 keer van de nominale stroom bereiken, met name geschikt voor het testen van de stroomstroom.
3. Uitgangssimulatie -sequentie en storingssimulatie
In staat om de simulatietest van de stroomlijnstoornissen te simuleren.
Geavanceerde functies :
1. Built-in IEC Standard Test
De ingebouwde IEC-standaardtest kan direct worden opgeroepen.
2.3-fase werking en parallelle modus
Ondersteuning 3-fase werking, 3 eenheden parallelTechnische specificatie:
MODEL | SPS300VAC15000W | ||
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 90A | |
5 |
Power Factor @220Vac Input ,Full Load |
0.99 Min. Active PFC | |
6 | Effieciency |
>87% Max >86% @220Vac,50HZ input/230Vac,50HZ output |
|
3-Phase Output Mode | |||
7 | AC Power(Per Phase) | 5000VA | |
8 | AC Power(Total) | 15000VA | |
9 |
Max.Current (r.m.s) |
0~150V(L) | 46A |
0~300V(H) | 23A | ||
10 |
Max.Current (Peak) |
0~150V(L) | 184A |
0~300V(H) | 92A | ||
Parallel Phase Mode | |||
11 |
Max.Current (r.m.s) |
0~150V(L) | 138A |
0~300V(H) | 69A | ||
12 |
Max.Current (Peak) |
0~150V(L) | 552A |
0~300V(H) | 276A | ||
13 | Phase | 1 Phase | |
OUTNPUT | |||
14 | Total Harmonic Distortion(THD) |
<0.5% (Resistive Load) at 15.0 -
70.0Hz and output voltage within the 80 - 140Vac at Low Range or the 160 -
280Vac at High Range <1% (Resistive Load) at 70.1 - 500Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range <1% (Resistive Load) at 501 - 1000Hz and output voltage within the 100 - 140Vac at Low Range or the 160 - 280Vac at High Range |
|
15 | Crest Factor(CF) | ≤4 | |
16 | Load Regulation |
+/-0.2%FS @15-100HZ(Resistive
Load) +/-0.5%FS @ Others Freq.(Resistive Load) |
|
17 | Line Regulation | ±0.1V | |
18 |
Voltage(AC) (L-N) |
Range | 0~300VAC, 150V/300V/Auto Mode |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
19 |
Phase
Angle (Starting/Ending) |
Range | 0~359.9° |
Resclution | 0.1° | ||
Accuracy | ±1° @45~65Hz | ||
20 | Voltage(DC) | Range | 0~424VDC |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
DC Power |
5000W | ||
Max.Current (L/H Range) (Per Phase) |
L 32.6A | ||
H 16.3A | |||
DC Power(Total) | 15000W | ||
Max.Current (L/H Range) (Total) |
L 97.8A | ||
H 48.9A | |||
Ripple&Noise(r.m.s) |
L <700mVrms
@Bandwidth 20HZ to 1MHZ |
||
Ripple&Noise(Peak) | <4000mVp-p @Bandwidth 20HZ to 1MHZ | ||
21 | Current OC Fold Mode | Resclution | 0.1A |
Accuracy | 2.0% of setting +1.0%F.S. | ||
Response Time | <1400ms | ||
22 | Frequency | Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.03% of setting | ||
23 | Progrmmable Output Impedance | Not Support | |
24 | Harmonic & Inter-harmonics Simulation | Not Support | |
MEASUREMENT(Per Phase) | |||
25 |
Voltage (Per Phase) |
Range | AC 0~300VAC |
DC 0~424VDC | |||
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S. (Notes: Vpeak: 0.6% of setting +1%F.S.) | ||
26 |
Frequency (Per Phase) |
Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.1% of setting | ||
27 |
Current* (r.m.s) (Per Phase) |
Range | H 0.3A~46A |
M 0.2A~20A | |||
L 0.1A~5A | |||
mA 0.02A~1.5A | |||
Resclution | 0.01A | ||
Accuracy | 0.4%+1.0%F.S. | ||
28 |
Current* (PEAK) (Per Phase) |
Range | 0A~188A |
Resclution | 0.01A | ||
Accuracy | 0.4%+1.5%F.S. | ||
29 |
Power (Per Phase) |
Range | 0~5100W |
Resclution | 0.1W | ||
Accuracy | 0.4% of setting +0.3%F.S at PF>0.2, Voltage >5V | ||
30 |
Power
Apparent |
Range | 0~5100VA |
Resclution | 0.1VA | ||
Accuracy | Voltage*Irms,Calculated value | ||
31 |
Power Resistive (VAR) (Per Phase) |
Range | 0~5100VAR |
Resclution | 0.1VAR | ||
Accuracy | √[(VA)^2-(W)^2],Calculated value | ||
32 |
Power Factor (PF) |
Range | 0.00~1.00 |
Resclution | 0.01 | ||
Accuracy | W/VA, Calculated value | ||
33 | Harmonic | Range | Not Support |
Extra Function | |||
34 | Slew Rate | Range | AC Voltage 0.001-1200.00V/mS and Disable |
DC Voltage 0.001-1000.00V/mS and Disable | |||
Frequency 0.001-1600.000HZ/ms and Disable | |||
35 | Remote Sense | Range | 5V(RMS), Max. Total power less than rated power |
36 | Cablibration |
Firmware-based cablibration through
the digital interface or front panel display Noted: Need Factory setting |
|
37 |
Test Mode | Not Support | |
38 | Graphic Display | 5.6'' Color touch LCD | |
39 | Operation Key Feature | Soft key,Numberic key,Rotary Knob,Support USB disk | |
40 | Rack mount Handles | YES | |
41 | FAN | Temperature Control | |
42 | Protection Circuits | OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP | |
43 | Interface | Standard USB,RS485,RS232, Option GPIB interface | |
Environmental | |||
44 | Operating Temperature | 0°C to 40°C | |
45 | Storage Temperature | -40°C to 85°C | |
46 | Altitude | 2000m | |
47 | Relative Humidity | 5-95%, non-condensing | |
48 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at FREQ | |
Mechanical | |||
49 | Dimensions(W*H*D) | 560x945x700 mm | |
50 | Unit Net Weight | 157.0kg |
Product Categorie : AC-bronsysteem in drie fasen > 15000W driefasig AC-bronsysteem
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.